Data Logger
Because of its modular expandability, the UDAP-MSR4 can be used as a powerful yet inexpensive data logger.
- remote configuration by UBIS4
- integrated temperature and humidity sensor
- supports the Bavaria-Hessia-Protocol and other network protocols
- supports intrument-clocked recording of measured values (exact to the second) for condensation particle counters from vendors TSI and Grimm
- single measured values can be tranfered to UBIS4, for further analysis and export (indefinite storage in UBIS4)
- optionally available with a 7"-touchscreen
- external modules for serial ports (RS-232, RS-422, RS-485), analog input and digital input
- automatic detection of analyzers by the Bavaria-Hessia-Protocol or UIDEP
- Extension scripts with a web user interface allow for additional functionality (e.g. monitoring of digital inputs, sampler control etc.)
Calibration software
The calibration software which is integrated in the UDAP4 gets its configuration from UBIS4 and allows performing calibrations, lack-of-fit and converter efficiency evaluations.
- Can control several calibrators simultaneously
- Gets the measured values of the examinee directly from the data logger software
- Outputs calibration protocols and CSV files containing the collected values
- Automatic transfer of output files to UBIS4, files are associated with the analyzers
State-of-the-art Technology
- based on Raspberry Pi
- optionally equiped with a serial port and analog inputs
- additional serial ports, analog inputs and digital inputs and outputs available through LAN-modules
- remote controlled by UBIS4
- built-in web user interface in the style of UBIS4
Raspberry Pi is a trademark of the Raspberry Pi Foundation
Versatile and Extendable
External moduls provide almost limitless expendability:
- Connection to UDAP-MSR4 by LAN
- automatic configuration by the UDAP-MSR4
- X410 for digital input and output
- X418 for analog inputs
- EX-6114 for RS-232
- EX-6124 for RS-232/422/485
Protocol Converter
Used as a protocol converter, the UDAP reads internal parameters of an analyzer in the vendor specific protocol and provides that data to the auquisition and monitoring system in the standardized Bavaria-Hessia-Protocol.
There are two uses cases for that:
- The analyzer provides the measured values in the Bavaria-Hessia-Protocol, but it could provide additional internal sensor data - useful for maintenance and quality assurance - in the vendor specific protocol
- The analyzer does not not offer any protocol that the aquisition and monitoring system supports
The protocol converter currently supports these analyzer types:
- Sharp 5030 particle matter analyzer
- Grimm CPC condensation particle counter
- Grimm EDM dust monitor
- Mela temperature and humidity sensor
- Parschmann temperature and humidity sensor
- Teledyne API (various analyzers)
- Thies Ultrasonic Anemometer 3D
- Vaisala Weather Transmitter WXT520
- Go-Sys BlueBox
- Hach-Lange sc1000
- Kunak Air A10
- Lambrecht THP-Sensor 8095
- Memmert constant climate chamber
- Vaisala Air Quality Transmitter AQT400
- Tekran 2537A
- Horiba 370 series
- Palas Fidas 200
- Metek Ultrasonic 3D anemometer
- TEOM 1400ab particle matter analyer
- TSI CPC condensation particle counter
- Gill anemometer